Solar Trampoline Park / FEC Calculator

Calculate solar ROI for your trampoline park or family entertainment center — enter facility size, trampoline area, arcade game count, kitchen type, HVAC tonnage, party rooms, and monthly bill. Get system size, HVAC + arcade + kitchen load breakdown, MACRS depreciation, and 25-year NPV.

sq ft
sq ft
games
tons
rooms
hrs/day
$/mo
Solar system for your trampoline park / FEC
188 kW system (447 × 420W panels) — 25% energy offset
Estimated usable roof area15,000 sq ft
Load — HVAC48.0 kW — largest load
Load — arcade / games28.0 kW during operation
Load — kitchen / food service25.0 kW
Load — lighting (high-ceiling LED)40.0 kW
Load — party rooms (HVAC + AV)6.0 kW
Annual solar production290,175 kWh/yr
Annual electricity savings$36,272/yr
Gross system cost$468,750
Federal ITC (30%)-$140,625
Year 1 MACRS tax savings-$35,859
Combined first-year tax benefit$176,484
Effective cost after tax benefits$292,266
Payback period8.1 yrs
25-year NPV (5% discount)$192,973
Demand charge reduction (est.)~$7,254/yr
Eco-FEC family marketing value (est.)~$5,760/yr
Annual CO2 reduction56.0 tons/yr
Link copied to clipboard

How to Use This Calculator

Facility size and active trampoline area

Family entertainment centers (FECs) and trampoline parks are among the highest per-square-foot electricity consumers in commercial real estate. Enter your total facility size and active trampoline area separately — active zones generate intense body heat that drives HVAC load beyond what standard commercial sizing accounts for. A 20,000 sq ft facility with 10,000 sq ft of active trampolining requires approximately 40 tons of HVAC — nearly double the standard commercial HVAC rule of thumb.

Arcade games and kitchen load

Arcade and redemption games average 350W each and run during all operating hours — 80 machines adds 28 kW of constant load. For large FECs with 200–400 machines, arcade load alone can account for 20–30% of total electricity consumption. Kitchen load varies dramatically: a full commercial kitchen with multiple fryers, grills, and pizza ovens draws 20–30 kW. Snack bars with warmers and refrigeration draw 5–10 kW. The calculator estimates the appropriate kitchen load based on your food service type.

Operating hours and party rooms

FECs typically operate 12–16 hours per day. Longer hours mean more electricity consumed per year — and more time when solar production can directly power operations. Party rooms add HVAC load and AV equipment, but critically they're used most heavily on weekend afternoons — exactly when solar production peaks. This temporal alignment between peak revenue events and peak solar generation is a meaningful advantage for FEC operators.

The Formula

HVAC Load kW = HVAC Tonnage × 1.2 kW/ton Arcade Load kW = Games × 0.35 kW × (Hours ÷ 14 hrs normalized) Kitchen Load kW = 25 kW (full) | 8 kW (snack) | 2 kW (vending) Lighting Load kW = Facility sq ft × 2.0 W/sqft ÷ 1,000 Party Load kW = Party Rooms × 1.5 kW Usable Roof = Facility sq ft × 75% (large flat industrial roofs) System kW = min(kW for full offset, Max from roof) Annual Savings = Annual Bill × Offset % ITC (30%) + MACRS Year 1 = Combined first-year tax benefit Demand Reduction = Annual Savings × 20% (FECs have sharp demand spikes)

FECs benefit from a 75% roof efficiency factor because large industrial-style FEC buildings typically have minimal rooftop equipment relative to their footprint — HVAC units are often at grade or low-mounted. The 20% demand charge reduction estimate reflects that FEC afternoon peaks (birthday party rushes) align well with solar production hours, directly shaving the demand peak. Battery storage can increase this demand reduction to 30–40%.

Example

Jump Zone — 20,000 sq ft FEC, Florida, 80 arcade games

Jump Zone is a medium FEC in Florida with 10,000 sq ft of trampolines, 80 arcade/redemption games, a full commercial kitchen, 40 tons HVAC, 4 party rooms, and a $12,000/month electricity bill.

Facility size20,000 sq ft
Arcade games80 × 350W = 28 kW
HVAC40 tons
Monthly bill$12,000/mo ($144,000/yr)

Results

System size~175 kW
Energy offset~72%
Annual savings~$104,000/yr
Gross system cost~$437,500
First-year tax benefit (ITC + MACRS)~$172,000
Effective cost~$265,500
Payback~2.6 years
25-year NPV~$1.5M

Jump Zone's $144,000 annual electricity bill makes solar economics compelling — 72% offset translates to $104,000 in annual savings. The $1.5M 25-year NPV represents a transformative financial impact for a mid-size FEC. The ITC + MACRS first-year benefit of $172,000 means the effective cost is under $266,000 — a 2.6-year payback that beats almost every other capital investment available to an FEC operator.

FAQ

Trampoline parks and FECs are excellent solar candidates for several compounding reasons: (1) Very high electricity consumption — the combination of body heat, HVAC, arcade machines, kitchen, and lighting creates electricity bills among the highest per-square-foot of any commercial facility type. (2) Large flat roofs — industrial-style FEC buildings have large, unobstructed flat roofs with minimal equipment. (3) Peak demand timing — birthday party rushes and family visit peaks on weekend afternoons align with peak solar production hours. (4) Business tax incentives — ITC + MACRS accelerated depreciation create year-one tax benefits that typically cover 35–45% of system cost.
Yes — in a grid-tied solar system with net metering, your solar panels feed directly into your building's electrical panel. During operating hours (10am–8pm), solar power flows to all electrical loads simultaneously — HVAC, arcade machines, kitchen, lighting. The utility grid fills any shortfall. This is called "self-consumption": solar power you generate and consume on-site is worth the full retail rate per kWh (you avoid buying it from the grid), which is always more valuable than selling excess power back at net metering rates. Maximizing on-site self-consumption — by ensuring major loads like arcade games run during solar hours — maximizes your ROI.
Battery storage makes sense for FECs in two specific scenarios: (1) Demand charge shaving — if your utility has high demand charges ($10+/kW), a battery sized to shave your peak 15-minute demand can reduce bills significantly. The battery charges from solar during midday and discharges during the afternoon birthday party rush peak. (2) Critical backup — a power outage during a packed weekend can create safety risks with evacuation of children and loss of lighting. A battery provides 15–30 minutes of critical backup power for safe evacuation. For most FECs, battery storage adds meaningful but not transformative value — solar alone provides the bulk of the ROI. Model your specific utility tariff's demand charge structure before sizing a battery.
Parents — the primary decision-makers for FEC visits — respond positively to environmental messaging. Studies on family entertainment show that sustainability marketing can drive 3–8% higher customer preference in competitive markets. Solar supports marketing through: (1) Visible panels on the roof exterior signal commitment. (2) Digital solar monitors in the lobby showing real-time kWh generated and CO2 offset ("your birthday party was powered by sunshine"). (3) Social media content — solar panels are a natural photo and story opportunity. (4) School group marketing — many FECs target school STEM field trips, where solar installations become educational assets.

Related Calculators

Embed This Calculator

Free to embed on your website. Just copy this code:

<iframe src="https://solarsizecalculator.com/solar-trampoline-park-calculator"
  width="100%" height="750" frameborder="0"
  title="Solar Trampoline Park Calculator"></iframe>